Wednesday, May 4, 2016

Information About Single Incision Laparoscopic Surgery

By Margaret Bailey


Advancements in technology are leading to the invention of better and new approaches to surgical procedures in all fields of medicine. Single incision laparoscopic surgery, often abbreviated as SILS also goes by several other names. Some of those names include Single-port laparoscopy (SPL), single-port incisionlless conventional equipment-using surgery, single-port access surgery (SPA), and Single-access endoscopic surgery. Additional names are natural-orifice trannsumbilical surgery (NOTUS), laparo-endoscopic singular-site surgery (LESS), and one-port umbilical surgery (OPUS).

SILS is a technique in laparoscopic surgery that is still relatively new owing to its recent development. It is classified as a minimally invasive surgical operation because most of the process is done through one entry point. In most cases, the navel serves as the entry point into interior of the patient. Thus, because only one entry point is used, only a single tiny scar is left behind after the process has been completed.

Entry points are either 11mm or 22 mm incisions. One incision is utilized to minimize scarring and pain felt during and after the process. The use of one incision is opposed to the traditional laparoscopic procedure that uses multiple entry points. There are some of the most highly qualified specialists in SILS in New York. Therefore, it is quite advisable to consider visiting the city when in search of specialists in this process.

There are two categories of specialized surgical equipment used by SILS. The two broad categories are hand instruments and access ports instruments. Access ports instruments are of various types including the GelPOINT system, QuadPort+, TriPort15, Uni-X, SILS device, and TriPort+. The manufacturers of these instruments are different.

Conversely, three major configurations of hand instruments exist today. They are pre-bent rigid, standard, and articulating configurations. The development of standard hand tools has been happening for more than the previous 30 years. Rigid design is used in making them. SPL reduced triangulation instrument challenge has been solved through the invetion of articulation hand instruments.

Surgeons usually have to choose whether to utilize articulating or standard instruments and that decision is often influenced by a few factors. Some of the factors include, access port used, surgical skills of the surgeon, and cost. In terms of cost, articulating instruments are considerably more expensive than standard instruments. The use of specialized devices makes this surgical procedure more effective and safer.

There is a high level of awareness of SILS among surgical doctors currently. However, it cannot be performed by any surgeon. The process is very complicated since it involves using specialized instruments through limited access space. Thus, surgical doctors who perform this process are often highly skilled and trained in surgical operation. That has made the use of this process limited and negative perceptions have followed from the public too.

SILS can be applied in performing a wide range of surgeries. Some of the most the include colectomy, sleeve gastrectomy, hysterectomy, appendectomy, nephrectomy, adjustable gastric banding, and sacrocolpopexy among many others. In the United States, standard instruments dominate this field of surgical operation as opposed to specialized instruments.




About the Author:



No comments:

Post a Comment